SPECIFICATION
Application
Cleanroom supply- and return air, Inline & terminal filters
Filter Classification
E10-H14
Type
Deeper Cased, Minipleat Construction
Nominal Airflow (m/s)
0.75 - 3.25
Media
Waterproof micro glass fibres
Air Volume (m³/hr)
See data sheet
Gasket
2 Component polyurethane poured or flat Neoprene
Initial Pressure drop (Pa)
See data sheet
Separator
Thermoplastic hotmelt
Temperature (max)
70 ºC in continuous operation
Filter test
Conform EN1822 NEN-EN-ISO 29463
Frame
Extruded anodized alumunium